Frontćpanel keys in service mode, Performing tests and calibrations – HP 220 User Manual

Page 141

Advertising
background image

7Ć3

Calibrations

C3187Ć90000

FrontĆPanel Keys in Service Mode

Pressingany single frontĆpanel key in service mode performs the same operation as in

normal mode. However, in service mode, you can also use combinations of keys, to perform

the various service tests and calibrations. With this intent, the

Replot

key acts as a

SHIFT

key,

and the

Cancel

key acts as an

ALT

key.

The followingillustration indicates which service tests and calibrations are assigned to which

frontĆpanel keys. A frontĆpanel overlay is provided with this manual; you can place it over

the actual keys on the plotter. The designation of keys for service tests is also shown on the

service configuration plot.

Service

Configuration

Electrical

Test

Accuracy

Calib. Print

Accuracy

Calib. Read

Input/Output

Test

Stepper

Motor Test

Bail Sensor

Test

Bail Cycle

Test

Bail

Calibration

Servo/Encoder

Test

Setup-Sheet

Calibration

Media-Sensor

Calibration

SHGFO

LO

nilh dabNe

nilh dabNe

nilh .ce

nilh .ce

Service Monitor

with Shift + Alt

To check whether a DesignJet 220 plotter is in service mode, press the

ALT

and

SHIFT

keys

together, and then release them. If the plotter is in service mode, four LEDs

Draft, Final, Paper

and

Transl/Vellum

flash. Press any key and they stop flashing.

Performing Tests and Calibrations

The general procedure to perform a service test or calibration is as follows:

, Once in service mode (see previous page), hold down the

SHIFT

or

ALT

key, whichever is

appropriate for the service test you want to perform.

. Without releasingthe

SHIFT

or

ALT

key, press the key correspondingto the service test or

calibration you want to perform.

A Release the keys once the

Busy

LED lights up.

Procedures specific to each calibration are given on the following pages.