System errors – HP 220 User Manual

Page 155

Advertising
background image

8Ć7

Troubleshooting

C3187Ć90000

System Errors

System errors are associated with plotter hardware failure that needs to be repaired by a

Service or Customer Engineer. System errors are indicated by the Error LED lit and steady.

In the tables on the following pages, the symbol

represents the frontĆpanel

LEDs, where, in this case, the

Error

,

Paper

and

Ready

LEDs arelit and steady, and theother

LEDs areoff.

Error

and

Busy

LEDs lit and steady: Input/output errors.

LEDs lit and

steady

Error Number and

Description

Corrective Options

336. RSĆ232ĆC data overflow.

Data byte was not read before

another was entered into the

UART.

At thetimeof printing of this manual, this

error should be solved by replacing the main

PCA. If the problem remains, consult

recent service notes for a possible solution.

If no service note deals with this error,

report the problem to the HP Response

Center.

276. Failureof RSĆ232ĆC

loopback test.

Ensuretheloopback connector is the

appropriate one. / Replace main PCA.

340. Failureof centronics READ. Replace main PCA.

Error

Paper

Ready

Setup

Access

Cartridges

Align

Cartridges

Replot

Form

Feed

Plot

Quality

Media

Type

Cancel

Advertising
This manual is related to the following products:

200