7Ć10 Calibrations

C3187Ć90000

SetupĆSheet Calibration

This calibration calibrates the power of the LED situated on the cartridge carriage, for better

scanningof the setup sheet.
Perform the setupĆsheet calibration whenever:

D The EEROM is cleared
D The cartridge carriage is replaced
D The optical sensor on the cartridge carriage is replaced
D Problems frequently occur with setupĆsheet scanning

To calibrate the LED, perform the followingprocedure:

1 Enter service mode D page 7Ć2.
2 Load a blank sheet of paper.

o not use vellum, transparent or polyester media, or recycled paper.

3 Hold down the

ALT

key and press

Setup-Sheet Calibration

.

The plotter positions the cartridge carriage over the media. The carriage remains

there for about 1 minute with the red L

lit, while the plotter performs the

calibration. The plotter then ejects the sheet.

To verify that the calibration has been performed correctly, plot a service configuration

plot, D page 8Ć23, and look at the field entitled Setup Sheet LED Calibration formula."

A formula appears in this field. If the calibration has not been performed correctly, a

message, saying that the LED has not been calibrated for setup sheet, appears.