1 Remove the electronicsĆenclosure

cover D page 6Ć5.

2 Remove the window D page 6Ć15.

3 Remove the center cover D page 6Ć16.

4 D/A1Ćsize plotters only: Open the

flexible, DANGER HIGH VOLTAGE,

insulation cover.

5 Disconnect the trailingĆcable connector

from the main PCA.

6 Remove the two screws that attach the

toroidto the rear of the electronics

enclosure.

Flex the cover to open it. Do not detach

the cover from the plotter.

Trailing-cable

connector

7 Pull off the two endcaps of the toroid and

remove the toroidfrom the trailing cable.

Torx-10

If you are installing a new trailing cable,

make sure the main PCA is compatible

with it. (Details D chapter 9.)

6Ć29