7 Remove the screws that attach the

bottom coverto the plotter, and lift the

coverclearof the plotter.

D/A1Ćsize plotters have 8 screws.

E/A0Ćsize plotters have 10 screws.

Torx-20

Reassembling: Ensure that the two

flags on the media sensor are correctly

positioned (see following procedure).

8 Pull the media sensorstraight out

towards you, freeing it from the

underside of the entry platen.

9 Cut the plastic tie that fastens the

mediaĆsensorcable to the underside of

the entry platen.

10 Lift the media sensorand cable clearof

the plotter

Plastic tie

Take care not to cut the mediaĆsensor cable

itself.

C A U T I O N

Calibration: After having reassembled the

plotter, perform the mediaĆsensor calibration

(Details D chapter 7).