Model 590/592

Problem

Cause

Correction

POWER SECTION

With switch in

Open circuit

Check to see that unit is

POWER position,

plugged in

the fryer is com-

Check the breaker or fuse

pletely inoperative

at supply box

(NO POWER)

Check voltage at wall

receptacle

Check MAIN POWER

switch; replace if defective

Check cord and plug

• Check 15 amp fuses

Pressure will not

Exhaust line from solenoid

Turn unit off and allow

exhaust at end of

valve to exhaust tank

fryer to cool to release

cook cycle

clogged

pressure from frypot;

clean all pressure lines,

exhaust stacks, and exhaust

tank

Solenoid valve clogged

Check and clean solenoid

valve per maintenance

section on solenoid valve

Operating

Deadweight clogged

Turn unit off and allow

pressure too high

fryer to cool to release

pressure from frypot;

remove dead weight and

clean

Exhaust line to stack clogged

Clean exhaust line to stack

1-6

1103

DO NOT OPERATE UNIT IF HIGH PRESSURE CONDITIONS EXIST; SEVERE INJURIES

AND BURNS WILL RESULT. PLACE THE POWER/PUMP SWITCH IN THE OFF POSI-

TION IMMEDIATELY. RELEASE THE PRESSURE BY ALLOWING UNIT TO COOL. THE

PRESSURE WILL THEN DROP. DO NOT RESUME USE OF UNIT UNTIL CAUSE OF HIGH

PRESSURE HAS BEEN FOUND AND CORRECTED.