Henny Penny PFE-592 User Manual

Page 19

Advertising
background image

Model 590/592

To avoid electrical shock of property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

Replacement

1. If the tube is broken or cracked, the control will open,

shutting off electrical power. The control cannot be reset.

2. Drain shortening from the frypot and discard. A substance

in the tube could contaminate the shortening.

3. Remove control panel.

4. Loosen small inside screw nut on capillary tube.

5. Remove capillary bulb from bulb holder inside the frypot.

6. Straighten the capillary tube.

7. Remove larger outside nut that threads into pot wall, and

remove defective control from control panel area.

8. Insert new control and replace screws.

9. Uncoil capillary line, starting at capillary tube, and insert

through frypot wall.

To avoid electrical shock or other injury, run capillary

line under and away from all electrical power wires and

terminals. The tube must never be in such a position

where it could accidentally touch the electrical power

terminals.

10. Carefully bend the capillary tube as shown in photo and

place into bulb brackets.

1103

2-3

2-4. HIGH TEMPERATURE

LIMIT CONTROL

(Continued)