Henny Penny PFE-592 User Manual

Page 12

Advertising
background image

Model 590/592

Blown fuse or tripped

Reset breaker or replace fuse

circuit breaker at supply

box or control panel

Blown fuse in PC board

Replace glass fuse in board

Faulty POWER/PUMP switch.

Check POWER/PUMP switch

per maintenance section on

the POWER/PUMP switch

Faulty cord and plug

Check cord and plug

• Check power at receptacle

Faulty drain switch

Check drain switch per

maintenance section on

drain switches

Faulty PC Board

Remove and replace control

panel

Faulty high limit control switch

Check high limit control

switch per maintenance

section on the high limit

Drain valve open

Close drain valve

Possible faulty temperature probe

Replace temperature probe

Faulty contactor

Check contactor per maintenance

section on contactors

1-8

1002

Problem Cause

Correction

HEATING OF SHORTENING SECTION

Shortening will not heat