Problem

Cause

Correction

PRESSURE SECTION (Continued)

Pressure does not

Not enough product in fryer

Place proper quantity of

build

or product not fresh

fresh product within

frypot to generate steam

Metal shipping spacer not

Remove shipping spacer.

removed from dead weight

See Unpacking Section of

Operator ’s Manual

Lid open or not latched

Close and latch lid

Solenoid valve leaking or

Check or clean solenoid

not closing

valve per maintenance

section on the solenoid valve

Dead weight valve leaking

Repair per maintenance section on

deadweight valve

Pressure not programmed

Check programming

Lid gasket leaking

Reverse gasket or lid needs

adjusted; see Reversing the Lid

Gasket and Lid Adjustment

Sections

Safety relief valve leaking

Check and replace if necessary per

maintenance section on the safety

relief valve

• Pressure pad broken or crushed • Replace pressure pads