Henny Penny PFE-592 User Manual

Page 15

Advertising
background image

Model 590/592

1-4. ERROR CODES

In the event of a control system failure, the digital display

shows an error message. These messages are coded: “E04”,

“E05”, “E06”, “E41”. A constant tone is heard when an error

code is displayed, and to silence this tone, press any of the

product

buttons.

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E04”

Control board overheating

Turn switch to OFF position, then turn

switch back to ON; if display still shows

“E04”, the board is getting too hot; check

for signs of overheating behind the control

panel; once panel cools down the controls

should return to normal; if “E04” persists,

replace the control

“E05”

Shortening overheating

Turn switch to OFF position, then back to

ON; if display shows “E05”, the heating

circuits and temperature probe should be

checked; once the unit cools down, the

controls should return to normal; if “E05”

persists, replace the controls

“E06”

Temperature probe failure

Turn switch to OFF position, then back to

ON; if the display shows “E06”, the tem-

perature probe should be checked; once the

temperature probe is repaired, or replaced,

controls should return to normal; if “E06”

persists, replace the controls

“E41”

Programming Failure

Turn switch to OFF position, then back to

ON. If display shows “E41”, the control

should be re-initialized (see programming

section); if the error code persists, replace

the control panel.

“E71”

Pump motor relay failure or

Replace relay if contacts are stuck closed;

wiring problem

check wiring on POWER/PUMP switch, or

wall receptacle; L1 and N may be reversed

1103

1-11

Advertising
This manual is related to the following products: