Henny Penny PFE-592 User Manual

Page 31

Advertising
background image

Model 590/592

DO NOT PULL THE RING ON THE SAFETY
RELIEF VALVE. HOT STEAM WILL BE
RELEASED AND SEVERE BURNS WILL RESULT.

1. At the end of each day’s usage of the fryer, the deadweight

valve must be cleaned. The fryer must be OFF and pressure

released. Open the lid and then remove the deadweight

valve cap and deadweight.

Failure to clean the deadweight assembly daily could
result in the fryer building too much pressure. Severe
injuries and burns could result.

2. Wipe both the cap and weight with a soft cloth. Make

certain to thoroughly clean inside cap, the weight seat, and

around deadweight orif ce.

3. Dry the parts and replace immediately to prevent damage

or loss.

The safety relief valve should be cleaned once a year.

DO NOT ATTEMPT TO REMOVE SAFETY VALVE
WHILE FRYER IS OPERATING, OR SEVERE
BURNS OR OTHER INJURIES WILL RESULT.

1. Remove pressure gauge.

1103

2-15

2-16. DEADWEIGHT VALVE

(Continued)

2-17. REMOVAL & CLEANING
OF SAFETY RELIEF
VALVE

ORIFICE CAP DEADWEIGHT

SAFETY RELIEF VALVE