Henny Penny PFE-592 User Manual

Page 38

Advertising
background image

Model 590/592

Upon pulling out on the drain handle, the microswitch should

be activated and the unit will not heat, but when the handle is

pushed back, the unit should operate properly. The bracket on

the microswitch is slotted so it can be adjusted backward or

forward.


1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. The following check should be made to determine if the

drain switch is defective.

a. Remove bracket from the unit.

b. Remove wires from the switch.

c. Check for continuity across the two outside terminals

on the drain switch. If circuit is open, the Drain Switch

is bad. The circuit should only be opened by pressing

on the actuator of the Drain Switch.

3. To replace switch, remove switch from the bracket, and

install switch in reverse order.

4. Test to see if drain valve handle actuates the switch. The

gap between the drain switch and the shaft should be no

more than 1/8” (3 mm).

HINT: Listen for audible click of switch while pulling drain

valve handle.

2-22

1103

2-21. DRAIN MICROSWITCH

1/8” (4 mm) Gap