Model 590/592

2. Use a wrench to loosen the valve from the pipe tee, turn

counterclockwise to remove.

3. Clean the inside of the pipe tee with hot water.

Turn the safety relief valve towards the rear of the fryer

when reinstalling safety relief valve.

4. Immerse the safety relief valve in a soapy water solution

for 24 hours. Use a 1 to 1 dilution rate. The valve cannot

be disassembled. It is factory preset to open at 14 1/2

pounds of pressure. If it does not open or close, it must

be replaced.

DO NOT DISASSEMBLE OR MODIFY THIS VALVE.
TAMPERING WITH THIS VALVE COULD CAUSE
SERIOUS INJURIES AND WILL VOID AGENCY

APPROVALS AND APPLIANCE WARRANTY.

Calibration Steps

The pressure gauge can be recalibrated should it be out of

adjustment.

1. Remove the rim and glass.

2. If the indication hand shows a pressure or vacuum reading

when it should stand at “0”, turn the recalibrator screw

in the same direction in which the indicating hand is to

be moved until the hand stands a proper “0” position.

3. Replace the rim and glass.

Cleaning Steps

1. Remove the gauge and check inside the pipe f ttings from

deadweight body. Make certain f ttings are clean and open.

2. Clean and reinstall the gauge.