Henny Penny PFE-592 User Manual

Page 30

Advertising
background image

Model 590/592

13. Wet “O” ring around seat with water and insert O-ring

assembly (f at side f rst) in valve through “IN” side of

body. Use an eraser end of pencil and press in the Tef on

seal until it snaps into place. Be careful not to mar or nick

the seat.

The smallest nick can cause a pressure leak. Replace all

O-ring seals that are in the parts kit and reassemble the

valve.

14. If the complete valve is to be replaced, follow steps 1, 2, 3,

4, 5, 7, 8 and 9 in this section.

DO NOT ATTEMPT TO REMOVE DEADWEIGHT
CAP WHIILE FRYER IS OPERATING. SEVERE
BURNS OR OTHER INJURIES WILL RESULT.

The operating valves are located behind the lid. The valve, left of

the pressure gauge, is a 14 1/2 lb. (999 mbar) safety relief valve,

and the one on the right is the deadweight valve.

Valves are working properly , when the pointer on the gauge is

in the “OPERATING ZONE” (green area). The gauge pointer

should not normally exceed the operating zone. If the pressure

builds to 14 1/2 lbs.(999 mbar), the safety relief valve will open

to release steam pressure from inside frypot.

2-14

1103

2-15. SOLENOID VALVE
(Continued)

2-16. DEADWEIGHT VALVE

Deadweight valve