The electric fryer requires two switching contactors: a primary

and a heat contactor. The primary contactor energizes (contacts

close) any time the POWER/PUMP switch is in the POWER

position, and the temperature of the shortening is below 420

° F

( 215° C). The high limit cuts power at the primary contactor

if the temperature of the shortening is above

420

° F ( 215° C).

The primary contactor supplies power to one side of the heat

contactor.

The heat contactor is controlled by the computer controller.

When the controller calls for heat, the heat contactor applies

power to one side of the heating elements. When the heat con-

tactor and primary contactor are energized (contacts closed) the

electric heating elements heat the shortening.

The photo shows a mercury heat contactor, but CE coun-

tries will have an electromechanical heat contactor.

Checkout

1. Remove electrical power supplied to the fryer.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. Remove the control panel.

3. Label and remove wires from contactors and perform a

check on both contactors as follows:

Test Points Results

From 23 to 29

open circuit

From 24 to 28

open circuit

From 25 to 27

open circuit

From 30 to 34

open circuit

From 31 to 35

open circuit

From 32 to 36

open circuit

From 33 to 37

ohm reading 1700

From 22 to 26

ohm reading 415

2-19. CONTACTORS

Primary

Heat

1103

2-17

30 31 32

34 35 36