Freezers – continuous operating mode – Hoshizaki HUR40A(-D) User Manual

Page 15

Advertising
background image

15

2. Freezers – Continuous Operating Mode

a) Sequence of Operation

Note:

1) Cut-on, cut-off, and cabinet temperature are read by the same sensor, called the

"cabinet thermistor."

2) The defrost thermistor reads the evaporator temperature.
3) There is a five second evaporator fan startup delay when the compressor and

fan would otherwise start together.

Five minutes after
defrost heater off
1. Compressor on
2. Condenser fan on

Five minutes after
compressor start-up
1. Evaporator fan(s) on

Eight minutes after evaporator
fan start-up "dF" no longer
displayed, cabinet temperature
displayed

Board Self Check
1. Frame heater(s) on
2. Evaporator fan(s) on

POWER ON

2 minute delay
1. Compressor start-up
2. Condenser fan start-up

Cycle Off (Cut-out
temperature reached)
[Minimum 2 minutes]
1. Compressor off
2. Condenser fan off

Continue as
normal cycling

Cycle On (Cut-on
temperature reached)
[Minimum 2 minutes]
1. Compressor start-up
2. Condenser fan start-up

Defrost end
Defrost thermistor
reaches defrost
termination
temperature, or defrost
timer reaches 1 hour
Defrost heater off

Defrost Start
Preprogrammed time interval
1. Compressor off
2. Evaporator fan(s) off
3. Condenser fan off
4. Defrost heater on
5. "dF" displayed

Advertising
This manual is related to the following products: