5

Undercounter Model Names
The undercounter models covered in this service manual initially had different model
names. If you have a unit with an auxiliary code of N-6 and a serial number ending in "H",
refer to the table below.

Model Name on
Nameplate

Current
Name

UR1-SSB

HUR40A

UR2-SSB

HUR68A

UF1-SSB

HUF40A

UF2-SSB

HUF68A

I. Specifications

A. Nameplate Ratings

Design Pressure

(PSIG)

Refrigerant

(oz.)

Model

AC Supply Voltage

Amperes

HI

LO

404A

134a

HUR40A(-D), HWR40A(-D)

115/60/1

5.0

240

120

15.2

HUR68A(-D), HWR68A(-D)

115/60/1

5.0

240

120

15.2

HUR96A(-D), HWR96A(-D)

115/60/1

6.0

240

120

15.2

HUF40A(-D), HWF40A(-D)

115/60/1

5.5

450

250

14.1

HUF68A(-D), HWF68A(-D)

115/60/1

10.0

450

250

13.0

Model

Door Opening mm

Total Refrigerated

Volume ft

3

Total Shelf

Space ft

2

Hotel Pan

Capacity (-D)

Width

Height

HUR40A(-D), HWR40A(-D),
HUF40A(-D), HWF40A(-D)

570.2

616.2

8.5

7.6

4

HUR68A(-D), HWR68A(-D),
HUF68A(-D), HWF68A(-D)

18.8

17.1

8

HUR96A(-D), HWR96A(-D)

29.1

26.6

12

B. Dimensions