Hoshizaki HUR40A(-D) User Manual

Page 44

Advertising
background image

44

Problem

Possible Cause

Remedy

[9] Defrost cycle

lasts too long.

a) Defrost Thermistor

1. Defective.

1. Replace.

b) Control Board

1. Defective.

1. Replace.

c) Defrost

1. Not enough defrosts

occurring per day.
Operation in humid
conditions.

1. Factory default is once every

6 hours. If coil is frosting too
much, can shorten defrost
interval.

d) Defrost Heater

1. Defective.

1. Replace heaters.

e) Safety Defrost

Thermostat

1. Defective, turning off

heaters prematurely,
or fused open.

1. Replace safety defrost

thermostat.

[10]Condensate

water overflow.

a) Cabinet Contents

1. Loading of large

volumes of warm,
moist, uncovered
product.

1. Cover product with plastic

wrap.

b) Location of Unit

1. Unit located near high

humidity source such
as fryer, steamer, etc.

1. Relocate.

c) Seals

1. Poor sealing around

evaporator, door
gaskets.

1. Adjust or replace.

d) Environment

1. Extreme environment

and door-opening
conditions.

1. Adjust conditions.

[11] Abnormal Noise

a) Fasteners

1. Loose fasteners allow

vibration of part.

1. Tighten fasteners.

b) Compressor

1. Problem with mount.

1. Properly mount compressor.

Replace any missing
grommets.

2. Floodback to

compressor.

2. Check for signs of floodback

to compressor. Evacuate and
recharge if necessary.

3. Defective.

3. Replace.

c) Fan

1. Fan blade loose.

1. Adjust and tighten.

2. Defective motor.

2. Replace.

d) Relay

1. Chattering.

1. Replace.

Advertising