Settings and diagnostics menu – Hoshizaki HUR40A(-D) User Manual

Page 26

Advertising
background image

26

Code Item

Setting and Display Range

Default

Refrigerator

Freezer

Auxiliary Code

1

section

2

section

Q5 and

earlier

Q6 and

later

F0 Defrost Interval

1 to 12 hours in 1 hour increments

6

6

6

F1 Defrost Termination

Temperature

Refrigerator: 59 to 68°F (15 to 20°C) in
one degree increments
Freezer: 41 to 68°F (5 to 20°C) in one
degree increments

59°F

59°F

41°F

F2 Setpoint

Temperature
Differential
(upper and lower)

0 to 6.3°F in increments of .9°F
(0 to 3.5°C in increments of .5°C)

0°F, -45°F

(0°C,

-2.5°C )

(decimal

is not

displayed)

0°F, -36°F

(2.0, -

2.0°C)

(decimal

is not

displayed)

0°F, -63°F

(0°C,

-3.5°C)

(decimal

is not

displayed)

0°F, -36°F

(2.0,

-2.0°C)

(decimal

is not

displayed)

F3 High Temperature

Alarm Delay Time

0 to 180 minutes in 60 minute
increments
(0=0; 1=60; 2=120; 3=180 minutes)

2

2

2

F4 Low Temperature

Alarm Delay Time

0 or 60 minutes
(0=0; 1=60 minutes)

1

1

1

F5 Temperature Dis-

play

Fahrenheit or Celsius

°F

°F

°F

F6 Alarm History

Displays alarm history - maximum 8
alarms

NA

NA

NA

F7 Compressor Run

Time

Displays run time between two most
recent defrosts

NA

NA

NA

F8 Not Used

NA

NA

NA

F9 Not Used

NA

NA

NA

3. Settings and Diagnostics Menu

To gain access to the settings, see "II.D.1. Gaining Access to Settings and Diagnostics."
Once inside this menu, press the MANUAL DEFROST button to scroll through the menu
and the

unmarked, blank button at any point to view the current setting. Press the

MANUAL DEFROST button to return to the menu screen.