B. removal and replacement of refrigeration unit, C. removal and replacement of compressor – Hoshizaki HUR40A(-D) User Manual

Page 48

Advertising
background image

48

B. Removal and Replacement of Refrigeration Unit

1) Turn off the power supply, and unplug the unit.
2) Remove the front panel, then remove the wire guard located below the display panel.
3) Unhook the wiring connectors at the control box, then remove the two hex-head M6

attachment nuts and the M5 bolt.

4) Very carefully slide out the refrigeration unit. Support the evaporator as it clears the

evaporator case.

5) Replace the removed parts in the reverse order of which they were removed.
6) Replace the front panel and all other guards in their correct positions.
7) Plug in the unit, and turn on the power supply.

CAUTION

1. To avoid a gas leak, be sure to prevent the refrigeration piping from coming

into contact with the body when taking out and returning the refrigeration unit
to its original position.

2. Do not let the fan motor or high pressure pipe touch wires.

Refrigeration Unit

Front Panel

C. Removal and Replacement of Compressor

IMPORTANT

Always install a new drier every time the sealed refrigeration system is opened.
Do not replace the drier until after all other repair or replacement has been
made.

Note: When replacing a compressor with a defective winding, be sure to install a new

start capacitor, overload and start relay. Due to the ability of the POE oil in the
compressor to absorb moisture quickly, the compressor must not be opened
more than 15 minutes for replacement or service. Do not mix lubricants of
different compressors even if both are charged with the same type of refrigerant,
except when they use the same lubricant.

Advertising