2. Temperature Display
• Displays the cabinet temperature. The factory setting is °F. To change the display to the

°C scale, see "a) Switching the Display Between Fahrenheit and Celsius (F5)" below.

• The cabinet temperature is updated every 30 seconds.
• During defrost, "dF" is displayed in place of the cabinet temperature.

a) Switching the Display Between Fahrenheit and Celsius (F5)

The factory setting is °F. To change the display to °C, follow the steps below.

1) Press and hold both the

button and the

unmarked, blank button for 5 seconds.

"F5" appears in the display window. (If "F0" is displayed, press the MANUAL
DEFROST button until "F5" appears.)

2) Press the

unmarked, blank button to display the current setting (default: "F"). Press

the

up or

down button to switch to °C. Press the

unmarked, blank button

again to save the setting.

3) Press and hold both the

button and the

unmarked, blank button for 5 seconds.

The cabinet temperature will be displayed using the newly saved temperature scale.

4) Affix the "°C" label supplied with the unit to the display panel, covering "°F" but not the

display window.

b) Adjusting the Setpoint Temperature

The setpoint temperature is the temperature at which the compressor turns on. To set
the setpoint temperature, follow the steps below.

1) Press the

button to display the current setpoint temperature.

2) To change the setpoint, press and hold the

button while pressing the

up or

down button to raise or lower the setpoint.

Model

Allowable Setpoint Range

Default

Refrigerator (auxiliary code Q5 and earlier)

+21 to +53°F

(-6 to +12°C)

39°F

(4°C)

Refrigerator (auxiliary code Q6 and later)

37°F

(3°C)

Freezer (Door)

-13 to +19°F
(-25 to -7°C)

0°F

(-18°C)

Freezer (Drawer)

2°F

(-17°C)

3) After 10 seconds, the new setpoint will be saved automatically.

Note: For refrigerators, the temperature differential for the compressor to turn off is

-4.5°F (-2.5°C) for auxiliary code Q5 and earlier and -3.6°F (-2.0°C) for auxiliary
code Q6 and later. For 1-section freezers, it is -6.3°F (-3.5°C) and for 2-section
freezers, it is -3.6°F (-2.0°C).