Problem

Possible Cause

Remedy

[5] Cabinet

temperature too
high.

a) Setpoint and/or

Differential

1. Incorrect.

1. Correct setting(s).

See sections "II.D.2.b)" and
"II.D.3.c)" for defaults.

b) Door

1. Not sealing, opened

frequently or open for
long intervals.

1. Check for sealing, check for

door open at time of warm
cabinet temperature.

c) Defrost

1. Defrost time

insufficient to remove
frost.
Operation in humid
conditions.

1. See "[8] Evaporator does

not defrost completely."

d) Refrigerant

1. Leak.

1. Repair leak and recharge.

e) Fan Motor

1. Defective.

1. Check and replace.

f) Air Filter

1. Clogged.

1. Clean.

g) Condenser

1. Dirty.

1. Clean.

h) Thermistor

1. Defective.

1. Check and replace.

i) Control Board

1. Defective.

1. Replace.

j) Outside Heat Source

1. Too close to unit.

1. Separate unit from heat

source.

k) Air Flow

1. Blockage inside

interior.

1. Remove blocakge by removing

or redistributing food product.

l) Warm Food

1. Warm food recently

placed in refrigerator.

1. Allow time for unit to return to

setpoint temperature.

[6] Cabinet

temperature
display
indicator does
not illuminate
properly.

a) Power Supply

1. "OFF" position.

1. Move to "ON" position.

2. Loose connection(s). 2. Tighten or reconnect.
3. Failure or tripped

breaker.

3. Call electrician and/or reset

breaker.

b) Control Board

1. Defective.

1. Replace.

[7] Cabinet

temperature too
low.

a) Setpoint and/or

Differential

1. Incorrect.

1. Correct setting(s).

See sections "II.D.2.b)" and
"II.D.3.c)" for defaults.

b) Frozen Food

1. Frozen food recently

placed in refrigerator.

1. Allow time for unit to return to

setpoint temperature.

c) Thermistor

1. Defective.

1. Check and replace.

d) Compressor Relay

1. Defective; contacts

welded.

1. Replace.

e) Control Board

1. Defective.

1. Replace.

[8] Evaporator does

not defrost
completely.

a) Defrost Thermistor

1. Defective.

1. Check and replace.

b) Defrost

1. Not enough defrosts

occurring per day.
Operation in humid
conditions.

1. Factory default is once every

6 hours. If coil is frosting too
much, can shorten defrost
interval.

c) Defrost Heaters

1. Defective.

1. Replace heaters.

d) Safety Defrost

Thermostat

1. Defective, turning off

heaters prematurely,
or fused open.

1. Replace safety defrost

thermostat.

e) Defrost Heater

Temperature Fuse

1. Blown.

1. Determine why fuse blew.

Replace fuse.