F) temperature display scale (f5), G) alarm history (f6) – Hoshizaki HUR40A(-D) User Manual

Page 30

Advertising
background image

30

4) Press the

unmarked, blank button to save the setting.

5) Press the MANUAL DEFROST button to return to the menu screen. Press and hold

both the

button and the

unmarked, blank button for 5 seconds to exit the setting

mode and return to the temperature display.

6) If a jumper was present between connector K151 pins 7 and 8, reconnect it after all

setting and diagnostic work is complete.

f) Temperature Display Scale (F5)

For information about switching the display between °F and °C, see "D.2.a) Switching
the Display Between Fahrenheit and Celsius (F5)."

g) Alarm History (F6)

To view the alarm history, follow the steps below.

1) Make sure the jumper is removed between connector K151 pins 7 and 8 on the control

board. Otherwise you will not be able to access this setting. For details, see "D.1.
Gaining Access to Settings and Diagnostics."

2) Press and hold both the

button and the

unmarked, blank button for 5 seconds.

"F0" should appear in the display window. Press the MANUAL DEFROST button until
"F6" appears in the display window.

3) Press the

unmarked, blank button to display the alarm history. The alarms will be

displayed in reverse chronological order (newest to oldest - up to 8 alarms). When "--"
is displayed, you have reached the end of the alarm history and the display will begin
again.

Note: The alarms are as follows:

4) To reset the alarm history, press and hold both the

unmarked, blank button and the

MANUAL DEFROST button for 5 seconds.

5) Press the MANUAL DEFROST button to return to the menu screen. Press and hold

both the

button and the

unmarked, blank button for 5 seconds to exit the setting

mode and return to the temperature display.

6) If a jumper was present between connector K151 pins 7 and 8, reconnect it after all

setting and diagnostic work is complete.

Alarm Code Description

E1

High Temperature Alarm

E2

Low Temperature Alarm

E3

Defrost Alarm

E4

High Pressure Alarm

E7

Clogged Filter Alarm

E8

Defrost Temperature Sensor Malfunction Alarm

E9

Clogged Filter Sensor Malfunction Alarm

EA

EEPROM Write Error Alarm

ED

EEPROM Verification or Read Error Alarm