Warning – Hoshizaki HUR40A(-D) User Manual

Page 25

Advertising
background image

25

c) Cabinet Temperature Correction (calibration factor)

In cases where there is a discrepancy between the actual cabinet center temperature
and the displayed temperature for a particular model, a calibration factor is used to
correct the displayed temperature.

WARNING

This unit has been factory tested with the default settings listed. Avoid using
this function except to confirm that the setting is correct. If set incorrectly, the
display could show an acceptable temperature even though the temperature
is out of the proper range. This value should only be changed after consulting
with the factory.

To view the current value, follow the steps below.

1) Turn the power on while pressing the

up button. The current correction calibration

factor will be shown. If "18" is displayed, the value is 1.8°F (1.0°C). See the table below
for the default values.

2) If it is determined through discussion with the factory that the setting needs to be

changed, press the

up or

down button to increase or decrease the value.

3) Press the

button to save the new value.

4) Turn the power off and then back on. The unit will start running with the new value.

[Example]
When the average cabinet temperature is 5.4°F
(3.0°C) higher than the thermistor detected
temperature, change the correction calibration
factor to 5.4°F (3.0°C).

Cabinet Temperature Correction (Calibration Factor)

Default

Model

Setting Range

1-Section

2-Section

3-Section

Refrigerator

-9.9 to 9.9

°

F in 0.9

°

F increments

(-9.5 to 9.5

°

C in 0.5

°

C increments)

00 (0.0

°

F)

(00 (0.0

°

C))

36 (3.6

°

F)

( 20 (2.0

°

C))

Freezer

18 (1.8

°

F)

(10 (1.0

°

C))

45 (4.5

°

F)

(25 (2.5

°

C))

Advertising