Low Voltage
(92Vac

± 5% or less)

POWER OK

LED will turn off if voltage

protection operates.
The control voltage safeties automaticlly
reset when voltage is corrected.

7

High Voltage
(147Vac

± 5% or more)

Legend: Comp–compressor; DV–drain valve; FMS–self-contained fan motor; HGV–hot

gas valve; PM–pump motor; TXV–thermostatic expansion valve; WRV–water
regulating valve; WV–inlet water valve

[c] CONTROLS AND ADJUSTMENTS

CAUTION

Dip switches are factory set. Failure to maintain factory settings may
adversely affect performance and warranty coverage.

a) Default Dip Switch Settings

The dip switch is factory-adjusted to the following positions:

Control

Board

Program Ver.

(Auxiliary Code)

S1 Dip

Switch No.

1

2

3

4

5

6

7

8

9

10

P00013-02 2.5 or earlier

(V-0 or earlier)

KM-201BAH OFF OFF OFF OFF ON ON OFF ON OFF ON
KM-260BAH OFF OFF OFF OFF ON ON ON OFF OFF ON

KM-201BWH OFF OFF OFF OFF ON ON OFF ON ON OFF
KM-260BWH ON OFF OFF OFF ON ON ON OFF OFF ON

P01771-02

3.2

(V-1 or later)

KM-201BAH OFF OFF OFF OFF ON ON OFF ON OFF ON
KM-260BAH OFF OFF OFF OFF ON ON ON OFF OFF ON

KM-201BWH OFF OFF OFF OFF ON ON OFF ON ON OFF
KM-260BWH OFF OFF OFF OFF ON ON ON OFF ON OFF

Control Board

Program Ver.

(Auxiliary Code)

S2 Dip Switch No.

1

2

3

4

5

6

P00013-02

2.5 or earlier

(V-0 or earlier)

KM-201BAH

ON

OFF OFF OFF OFF

ON

KM-260BAH

ON

OFF OFF OFF OFF

ON

KM-201BWH

ON

OFF OFF OFF

ON

OFF

KM-260BWH

ON

OFF OFF OFF

ON

OFF

P01771-02

3.2

(V-1 or later)

KM-201BAH

ON

OFF OFF OFF OFF OFF

KM-260BAH

ON

OFF OFF OFF OFF OFF

KM-201BWH

ON

OFF OFF OFF OFF OFF

KM-260BWH

ON

OFF OFF OFF OFF OFF

Do not adjust the S2 dip switch. These must be left in the factory default position, or the
unit will not operate properly.