Hoshizaki KM-260BAH User Manual

Page 35

Advertising
background image

30

[b] KM-260BAH

10sec

10sec

10sec

10sec

10sec

10sec

10sec

10sec

10sec

10sec

HARVEST CYCLE

Thermistor senses 9°C

after 6 min to 8 min 50 sec

in harvest cycle (Ver 3.1 or

later)

6min

60sec

HARVEST CYCLE

Thermistor senses 9°C after more than

8 min 50 sec in harvest cycle (Ver 3.1

or later)

6min

3min

10sec

FREEZE CYCLE

PART NAME

HARVEST CYCLE

(INITIAL)

FREEZE CYCLE

HARVEST CYCLE

(AFTER BIN FULL)

HARVEST CYCLE

(INCLUDING DRAIN)

FREEZE CYCLE

F

REEZE CYCLE

H

ARVEST CYCLE

BIN FULL

HOT GAS VALVE

FAN MOTOR

ON

OFF

ON

Program Ver 2.5

or earlier

(Auxiliary Code:

V-0 or earlier

)

ON

OFF

WATER VALVE

ON

OFF

CLEANING VALVE

ON

OFF

DRAIN VALVE

FLOAT SWITCH

ON

RELAY: X4

(WV)

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

CONT

ROL B

OA

RD

RELAY: X6

(DV)

RELAY: X1

(COMP)

RELAY: X2

(HV/FM)

ON

RELAY: X3

(PM)

OFF

OFF

BIN CONTROL

SWITCH

ON

OFF

OFF

PU

MP MO

TOR

Program Ver 3.2

or later

(Auxiliary Code:

V-1 or later

)

POWER SWITCH

ON

HARVEST CYCLE

COMPRESSOR

ON

OFF

1°C

OFF

9°C

5°C

THERMISTOR

Max 6 min

5 sec

Max 6 min

Max 6 min

10 sec

Max 6 min

15 sec

10 sec

90 sec

Max 6

10 sec

10 sec

10 sec

Max 6 min

10 sec

Max 6 min

Max 6 min

Advertising