Hoshizaki KM-260BAH User Manual

Page 65

Advertising
background image

60

13. WATER VALVE

1) Unplug the icemaker or disconnect the power source.

2) Close the water supply tap.

3) Remove the top panel, rear panel and side panel (R).

4) Disconnect the tab terminals.

5) Pinch and lower the hose clamp.

6) Disconnect the rubber hose from the water valve. Put a towel under the water valve

to receive water coming out.

7) Turn the inlet nut in the arrow direction to remove it from the water valve. Do not

lose the gasket inside.

8) Remove the two mounting screws.

9) Install the new valve in the reverse order of the removal procedure.

10) Tighten the inlet nut to a torque of 7.85 N•m (±5%) to prevent water leaks.

11) Open the water supply tap.

12) Plug in the icemaker or connect the power source.

13) Check for leaks.

14) Refi t the panels in their correct positions.

Fig. 10

Tab Terminal

Hose Clamp

Inlet Nut

Mounting Screw

Rubber Hose

Advertising
This manual is related to the following products: