Hoshizaki KM-260BAH User Manual

Page 58

Advertising
background image

53

Fig. 5

Remove Expansion
Valve Cover fi rst

Cut ties to make Bulb
removable

Bulb Insulation Hose

Expansion Valve

Bulb

7. AIR-COOLED CONDENSER

CAUTION

1. Always install a new drier every time the sealed refrigeration system is

opened.

2. Do not replace the drier until after all other repair or replacement has

been made. Install the new drier with the arrow on the drier in the
direction of the refrigerant fl ow.

3. When brazing, protect the drier by using a wet cloth to prevent the drier

from overheating. Do not allow the drier to exceed 250°F (121°C).

1) Unplug the icemaker or disconnect the power source.

2) Remove the panels.

3) Recover the refrigerant and store it in an approved container.

4) Disconnect the condenser inlet and outlet piping.

5) Remove the fan motor bracket from the condenser.

6) Remove the screws securing the condenser assembly, then remove the assembly.

Advertising
This manual is related to the following products: