Hoshizaki KM-260BAH User Manual

Page 71

Advertising
background image

66

[a] POWER SWITCH

1) Disconnect the tab terminals and remove the nut securing the power switch.

2) Install the new switch in the reverse order of the removal procedure.

3) To prevent miswiring, check the terminal numbers and lead wire colors with the

wiring label.

[b] FUSE

1) Use a phillips head screwdriver to remove the fuse holder cap and take out the fuse.

2) Install the new fuse in the reverse order of the removal procedure.

[c] FUSE HOLDER

1) Disconnect the tab terminal and remove the nut securing the fuse holder.

2) Install the new fuse holder in the reverse order of the removal procedure.

[d] CONTROL BOARD

1) Disconnect all the connectors.

2) Pull the tab to release the control board.

3) Lift off the control board.

4) To refi t the control board, fi t its four corner holes on the positioning lugs inside the

control box and secure the control board with the tab.

5) Check the dip switch for proper setting.

6) When reconnecting the connectors, do not push them too hard. The control board

may be damaged.

[e] POWER RELAY

1) Disconnect the tab terminals, remove the mounting screw, and lift off the power relay

from the fi t at the bottom.

2) Install the new relay in the reverse order of the removal procedure.