41

PROBLEM POSSIBLE

CAUSE

REMEDY

a) Inlet Water Valve

1. Diaphragm does not

close.

1. Check for water leaks

with icemaker off.
Replace if necessary.

[4] Water

continues to
be supplied in
freeze cycle.

b) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.

a) Water Supply Line

1. Water pressure too low

and water level in water
tank too low.

1. Check and get

recommended pressure.

b) Inlet Water Valve

1. Dirty mesh filter or

orifice and water level in
water tank too low.

1. Clean.

1. Water leaks.

1. Check connections for

water leaks, and replace.

c) Water System

2. Clogged.

2. Clean.

1. Motor winding opened.

1. Replace.

2. Bearing worn out.

2. Replace.

3. Wiring to pump motor.

3. Check for loose

connection or open, and
replace.

4. Defective capacitor.

4. Replace.

d) Pump Motor

5. Defective or bound

impeller.

5. Replace and clean.

[5] No water

comes from
Spray Tubes.
Water Pump
will not start, or
freeze cycle
time is too
short.

e) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.

1. Motor winding opened.

1. Replace.

2. Bearing worn out.

2. Replace.

3. Wiring to fan motor.

3. Check for loose

connection or open, and
replace.

a) Fan Motor

4. Fan blade bound

(locked fan motor).

4. Check and replace.

[6] Fan Motor will

not start, or is
not operating.

b) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.

1. Undercharged.

1. Check for leaks and

recharge.

a) Refrigerant

2. Air or moisture trapped.

2. Replace drier, and

recharge.

b) Compressor

1. Defective.

1. Replace.

[7] All

components
run but no ice
is produced.

c) Hot Gas Solenoid

Valve

1. Continues to open in

freeze cycle.

1. Check and replace.


Advertising