12. PUMP MOTOR

1) Unplug the icemaker or disconnect the power source.

2) Remove the top panel, rear panel and side panel (R).

3) Disconnect the connector of the pump motor lead.

4) Remove the water tank (see “19. WATER TANK”).

5) Remove the hose band connecting the pump motor discharge outlet and pull off the

rubber hose.

Fig. 8

6) Remove the screws securing the pump motor, and lift it off.

Hose Band

Rubber Hose

7) Install the new motor in the reverse order of the removal procedure.

8) Refi t the water tank in its correct position.

9) Plug in the icemaker or connect the power source, and check for leaks.

10) Refi t the panels in their correct positions.