background image

31

[c] KM-201BWH

30sec

30sec

30sec

30sec

30sec

30sec

30sec

30sec

30sec

30sec

HARVEST CYCLE

Thermistor senses 9°C after more than

8 min 30 sec in harvest cycle (Ver 3.1

or later)

HARVEST CYCLE

Thermistor senses 9°C

after 6 min to 8 min 30 sec

in harvest cycle (Ver 3.1 or

later)

6min

3min

30sec

6min

60sec

FREEZE CYCLE

HARVEST CYCLE

(AFTER BIN FULL)

BIN FULL

HARVEST CYCLE

F

REEZE CYCLE

FREEZE CYCLE

HARVEST CYCLE

(INCLUDING DRAIN)

DRAIN VALVE

HOT GAS VALVE

WATER VALVE

ON

OFF

OFF

CLEANING VALVE

ON

OFF

FLOAT SWITCH

ON

OFF

BIN CONTROL

SWITCH

ON

OFF

RELAY: X4

(WV)

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

CONT

ROL B

OA

RD

RELAY: X6

(DV)

RELAY: X1

(COMP)

RELAY: X2

(HV/FM)

ON

RELAY: X3

(PM)

OFF

FAN MOTOR

ON

OFF

ON

Program Ver 2.5

or earlier

(Auxiliary Code:

V-0 or earlier

)

ON

OFF

PU

MP MO

TOR

Program Ver 3.2

or later

(Auxiliary Code:

V-1 or later

)

POWER SWITCH

ON

HARVEST CYCLE

FREEZE CYCLE

HARVEST CYCLE

(INITIAL)

OFF

PART NAME

9°C

5°C

THERMISTOR

COMPRESSOR

ON

OFF

1°C

Max 6 min

5 sec

Max 6 min

Max 6 min

10 sec

Max 6 min

15 sec

10 sec

90 sec

Max 6 min

10 sec

10 sec

10 sec

10 sec OFF, 50 sec ON

10 sec OFF, 50 sec ON

10 sec OFF, 50 sec ON

10°C

10°C

10°C

10 sec

10 sec OFF, 50 sec ON

10°C

Max 6 min

Max 6 min