Hoshizaki KM-260BAH User Manual

Page 37

Advertising
background image

32

[d] KM-260BWH

10sec

10sec

10sec

10sec

10sec

10sec

10sec

10sec

10sec

10sec

HARVEST CYCLE

Thermistor senses 9°C

after 6 min to 8 min 50 sec

in harvest cycle (Ver 3.1 or

later)

6min

3min

10sec

6min

60sec

PART NAME

FREEZE CYCLE

HARVEST CYCLE

(INCLUDING DRAIN)

FREEZE CYCLE

HOT GAS VALVE

WATER VALVE

ON

OFF

CLEANING VALVE

HARVEST CYCLE

(AFTER BIN FULL)

BIN FULL

HARVEST CYCLE

OFF

DRAIN VALVE

ON

ON

OFF

ON

OFF

ON

RELAY: X3

(PM)

OFF

ON

OFF

ON

RELAY: X4

(WV)

FLOAT SWITCH

ON

OFF

BIN CONTROL

SWITCH

ON

OFF

OFF

ON

OFF

CONT

ROL B

OA

RD

RELAY: X6

(DV)

RELAY: X1

(COMP)

RELAY: X2

(HV/FM)

FAN MOTOR

ON

OFF

ON

Program Ver 2.5

or earlier

(Auxiliary Code:

V-0 or earlier

)

ON

OFF

PU

MP MO

TOR

Program Ver 3.2

or later

(Auxiliary Code:

V-1 or later

)

OFF

FREEZE CYCLE

HARVEST CYCLE

Thermistor senses 9°C after more than

8 min 50 sec in harvest cycle (Ver 3.1

or later)

ON

HARVEST CYCLE

FREEZE CYCLE

HARVEST CYCLE

(INITIAL)

OFF

ON

OFF

9°C

5°C

POWER SWITCH

THERMISTOR

ON

OFF

1°C

COMPRESSOR

Max 6 min

5 sec

Max 6 min

Max 6 min

10 sec

Max 6 min

15 sec

10 sec

90 sec

Max 6 min

10 sec

10 sec

10 sec

10 sec OFF, 50 sec ON

10 sec OFF, 50 sec ON

10 sec OFF, 50 sec ON

10°C

10°C

10°C

Max 6 minMax 6 min

10 sec

10 sec OFF, 50 sec ON

10°C

Max 6 min

Max 6 min