Hoshizaki KM-260BAH User Manual

Page 25

Advertising
background image

20

S2 Dip Switch Setting

Anti-Slush Control

No. 5

No. 6

OFF

OFF

Activated (Ver. 1.0)

ON

OFF

Activated (Ver. 2.0)

OFF

ON

Deactivated

ON

ON

Deactivated

Control Board P01771-02

j) Harvest Promotion Control (S2 dip switch 2) [Program Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate
properly.
When activated, this control promotes harvest of ice on the evaporator that is hard to
remove. If the harvest cycle exceeds 6 minutes, the pump motor starts to operate for a
maximum of 3 minutes.

S2 Dip Switch Setting

Harvest Promotion

Control

No. 2

OFF

Activated

ON

Deactivated

k) Refi ll Counter (S2 dip switch 3) [Program Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate
properly. The KM-201BAH/BWH and KM-260BAH/BWH do not refi ll.

l) Harvest Completion Detection Control (S2 dip switch 4) [Program Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate
properly.
It is deactivated on the KM-201BAH/BWH and KM-260BAH/BWH.
When activated, this control determines whether ice remains on the evaporator at the
end of a harvest cycle and at the beginning of a freeze cycle. If ice drops and activates
the bin control switch in the last 10 seconds of a harvest cycle, the control determines
that ice still remains on the evaporator and extends the harvest cycle for 30 seconds.
If the bin control switch is activated at the beginning of a freeze cycle, the control
determines that ice still remains on the evaporator and starts a harvest cycle after the
minimum freeze cycle time has passed.

S2 Dip Switch Setting

Harvest Completion

Detection Control

No. 4

OFF

Deactivated

ON

Activated