Framing & clearances, A. select fireplace location – Hearth and Home Technologies I60 User Manual

Page 18

Advertising
background image

18

6

6

Framing & Clearances

F

D

E

A

5/8 in. (16 mm)
all configurations

In an exterior
chase or projecting
into a garage

Across a
corner

As a room
divider

Along a wall

G

B A

G

G

B

A

48 in.

(1219 mm)

min.

H

A

H

Note:

Note:

I60 - 1 in. (25 mm)
I80 - 1 1/2 in. (38 mm)
minimum distance from
sides & back of fireplace to
combustible materials.
I60 & I80 - 1/2 in. (13 mm)
minimum at nailing flanges.

In addition to these
framing dimensions, also
reference the following
sections:
• Clearances (Section

6.B.)

• Mantel Projections

(Section 11.E.)

• Fireplace Dimensions

(Section 13.A.)

C

H

B

Figure 6.1 Fireplace Locations (Framing dimensions shown)

A. Select Fireplace Location

Model

A

B

C

D

E

F

G

H

I60

inches

45 1/2

53 1/2

85

42 1/2

19 3/8

60 1/8

28

24 in. (610 mm)

Minimum from FP opening to any

perpendicular wall.

mm

1156

1359

2159

1080

492

1527

711

I80

inches

52

59 1/2

92 3/4

46 3/8

21 1/2

65 5/8

28 1/2

mm

1308

1511

2356

1178

546

1667

724

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08