F. Sidewalls/Surrounds

• Adjacent combustible sidewalls must be located

a minimum of 24 in. (610 mm) from the fireplace
opening.

• Combustible or non-combustible mantel legs, surrounds

and stub walls may be constructed per Figure 11.12.

B

A

24 in.

[610 mm]

19 3/4 in.

[502 mm]

24 in.

[610 mm]

28 5/8 in.

[727 mm]

FLUSH

FRONT

4 in.

[102 mm]

BRICK

FRONT

50° angle

39° angle

Note: Grid depicts 1-in scale.

Figure 11.12 Mantel Leg or Wall Projections (acceptable on both sides of opening)

Model

A

B

I60

inches

36

45

mm

914

1130

I80

inches

42

50 1/2

mm

1067

1283

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08