Non-combustible sealant, Flush hearth extension framing – Hearth and Home Technologies I60 User Manual

Page 42

Advertising
background image

42

Non-combustible Sealant

After completing the framing and applying the facing
materials over the framing, a bead of non-combustible
sealant must be used to close off any gaps at the top and
sides between the fi replace hearth.

Non-combustible Sealant

Figure 11.6 Place Non-combustible Sealant

30 in. min.

12 in.

Min.

12 in.

Min.

Figure 11.7 Flush Hearth Extension

Flush Hearth Extension Framing

A raised hearth extension built fl ush with the fi replace
opening (Figures 11.7, 11.8) requires the fi replace to be
installed on a non-combustible surface.

Noncombustible Material

Protective Metal

Hearth Strip

30 in. Min.

Hearth Extension

Micore

Finished

Floor

Note: Maximum height from floor
under fireplace to top of finished
hearth extension is 7-5/8 in.

Figure 11.8 Flush Hearth Extension Side View

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

Advertising
This manual is related to the following products:

I80