E. Combustible Mantel

• See Figure 11.11.
• A combustible mantel may be positioned no lower than

12 in./305 mm (I60) or 20 in./508 mm (I80) above the
top of the fi replace opening.

• A combustible mantel may have a maximum depth of

12 in./305 mm.

• Combustible trim and materials cannot be placed within

6 in. (152 mm) of the fi replace opening (top or sides).

• Combustible materials projecting more than 1-1/2 in.

(38 mm) shall not be placed within 12 in. (305 mm) from
the top of the fi replace opening.

• Combustible trim must not cover the metal surfaces of

the fi replace.

• Mantel clearance is in accordance with Section 7-3.3.3

of ANSI/NFPA211.

12 in.

(305 mm)

55-1/2 in.

(1410 mm)

Effective

Height

*

Top of

Fireplace

Opening

*

I60 12 in./305 mm
I80 20 in./504 mm

Figure 11.11 Clearances to Mantels or other Combustibles above
Fireplace

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08