B. Clearances

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

(insulation)

0 in. to level

of standoffs

Attic

Insulation

Shield

(ceiling)

(roof)

(attic)

(ceiling)

Ceiling Firestop

Offset/Return (secured

with hanger straps)

Storm Collar

Roof Flashing

Clearance to back &

sides of appliance

I60 - 1 in. (25 mm)

I80 - 1 1/2 in. (38 mm)

(except at nailing flanges

where it is 1/2 in. [13 mm])

Must have 2 in. (51 mm)

minimum clearance

to header

0 in.

to floor

2 in. (51 mm) min.

Shaded areas

represent

2 in. (51 mm) min.

air space clearance

required around pipe

Combustible Object

48 in.

1219 mm

Adapter attached here (not shown)

Figure 6.2 Clearances to Combustible Materials

Note: Chimney air kit and 11-10 in./279-254 mm adapter are not shown,
but are required in Canada.