D. Finishing Material

Refer to Sections 11.A. and Sections 11.B. for combus-
tible/noncombustible materials. Refer to Figure 11.9 for
noncombustible zone.

WARNING! Risk of Fire! You must maintain clearances.
• Use only non-combustible framing material below

standoffs.

• Sheetrock, wood or other combustibles must NOT be

used as sheathing or facing in the noncombustible
zone.

DO NOT cover metal fi replace front with combustible

materials.

• Install combustible materials only to specifi ed clearances

on top front and side edges.

These surfaces
may be covered
with non-combustible
material.

Non-combustible
sealant.

Figure 11.9 Noncombustible Facing

Metal strips are placed 2 in. (51 mm)
under the front of the fireplace and must
extend beyond the front and sides of
fireplace opening by 2 in. (51 mm)

Continuous,
non-combustible sealant

Floor constructed of wood or
other combustible material

HX4 Hearth Ext
or equivilent
insulation

Finished combustible wall

Combustible material

Non-combustible
decorative facing
(up to full brick depth)

2 x 4 header, flush with
front of stand-offs

Tile, stone or other
non-combustible material

Flat 2 x 4 stud wall

Figure 11.10 Decorative Facing

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08