Hearth and Home Technologies I60 User Manual

Page 21

Advertising
background image

21

7

7

Installation of Fireplace

CAUTION! Risk of Cuts/Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.

A. Things to Consider

• Location of chimney air kit
• Location(s) of outside air kit
• Electrical connections and/or wall switch
• Gas line piping

Figure 7.1 Unpacking Back Refractory

Figure 7.2 Bending Refractory Shipping Tabs
Back Down

Remove back refractory from outside of fi replace by

bending tabs up and lifting refractory out of brackets.
See Figure 7.1.

• Bend tabs back down out of the way. See Figure 7.2. Do

not remove screws or brackets from fi replace. If brackets
are removed, fi ll holes in outer shell with screws.

• Repeat this process to remove side refractories.

D. Unpack the Fireplace (I80 only)

C. Secure the Fireplace (I60 only)

WARNING! Risk of Fire! Prevent contact with sagging,
loose insulation.

DO NOT install against vapor barriers or exposed
insulation.

• Secure insulation and vapor barriers.

• Provide minimum air space clearances at the sides
and back of the fireplace assembly as outlined in
Section 6.

• Place

the

fi replace on a continuous fl at surface.

• Follow framing instructions in Section 6.
• Slide

fi replace into position (brackets can be used to

anchor fi replace in position).

• Skip to Section 7.G. for further I60 instructions.

B. Unpack the Fireplace (I60 only)

• I60 is shipped with refractory in place.
• Remove

packaging.

• Remove shipping brackets as shown in Figure 7.8.

Replace the screws removed from the fi replace.

• Remove I60 from pallet and set in place.

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

Advertising
This manual is related to the following products:

I80