17

venting installation

Continued

10 FooT RUle

All flue gas outlet chimney terminations must extend

a minimum of 3 feet in height above the highest point

where it passes through the roof and must be at least

2 feet above the highest point of the roof that is within

a horizontal distance of 10 feet (see Figure 25).

FInIsHInG FIRePlaCe

Combustible materials, such as wallboard, gypsum

board, sheet rock, drywall, plywood, etc. may not

make direct contact with sides and top around the fire-

place face. See clearance requirements in Figures 8

and 9 on page 9. It is important that combustible ma-

terials do not overlap the face itself. Brick, glass, tile or

other noncombustible materials may overlap the front

face provided they do not obstruct essential openings.

When overlapping with a noncombustible facing ma-

terial, use only noncombustible mortar or adhesive.

MasonRY (PReCasT) CHIMneY

Masonry Chimney may be used instead of the FMI

Chimney System. Parts come in 14" Diameter and

can be obtained by FMI PRODUCTS, LLC. See Ac-

cessories on page 35.

24" Min.

24" Min.

18"

Min.

Typ.

Figure 24 - Multiple Chase Installation

10'

2' Min.

10'

3' Min.

2' Min.

3' Min.

Level of

Flue Gas

Outlet

Figure 25 - 10 Foot Rule

optional gas line installation

You may elect to add a vented decorative gas appli-

ance (gas log) to your Grand Meridian Fireplace. If

so, follow the installation instructions from the Deco-

rative Gas Appliance manufacturer. Familiarize your-

self with requirements for installation as outlined by

the National Fuel Gas Code, ANSI Z223.1/NFPA 54.

This gas pipe provision should only be used on a

decorative gas appliance.

You can route the gas piping practically anywhere in

the firebox – the floor, back wall or side walls. You

will just need a masonry drill; the instructions from

the gas appliance manufacturer will be very straight-

forward.
Fill in the holes you have drilled around the gas pip-

ing with the regular mortar.
Follow the Gas Log manufacturer’s instructions.

optional electrical connection installation

Like the gas line, electrical feed lines can be run

through the floor, back wall, or side walls. Follow

local building and electrical code requirements.