Supporting floor systems installation, Combustible floor installation, 8 " metal base (mmb63) – FMI MASONRY FIREBOX MM33 User Manual

Page 20: Ember protector strips

Advertising
background image

www.fmiproducts.com

125160-01A

20

1/2" Thick Cement Board Dimensions

Model

A1

A2

B1

B2

MM63

67"

28"

60"

23"

supporting Floor systems installation

Continued

Figure 29 - Anchorage Dimensions

Figure 30 - Hardware

Figure 31 - Typical Anchorage Layout

combustible Floor installation

8" MeTal Base (MMB63)

The Metal Base (MMB63) ensures the minimum

8" clearance above combustible flooring is main-

tained with Grand Meridian Model MM63.
A layer of 1/2" minimum Cement Board (Not Includ-

ed) is required on the top and mid section below as

shown in Figure 32, page 21. The required sizes are

shown in the table below.

IMPORTANT:

Remember to tighten up nuts below

the floor after fireplace installation in order to take up

any slack in the threads.

eMBeR PRoTeCToR sTRIPs:

Ember protector strips (included with Metal Base Kit)

are required between the front of the Fireplace Hearth

and Hearth Extension. A minimum thickness of 26

gauge metal strip at least 4" wide can be used. The

length needs to extend 2 inches beyond each side

of the fireplace opening. If two strips are used, make

sure they overlap at least two inches in the middle.

The strip is placed about 2" into the underside of the

platform at the front (Figure 10, page 10).
NOTE: When using an on-site constructed hearth ex-

tension, you may use a sand-cement grout between

the hearth and extension instead.

F

10"

4"

a

Model

a

MM33

32 ¾"

MM39

38 ¾"

MM44

43 ¾"

MM49

48 ¾"

MM63

62 ¾"

2” min

clearance

Fireplace

outline

10”

exaMPle onlY