Fireplace installation – FMI MASONRY FIREBOX MM33 User Manual

Page 28

Advertising
background image

www.fmiproducts.com

125160-01A

28

Fireplace installation

Continued

InsTallInG daMPeR / anCHoR PlaTe

(MM12aP) FoR PRe-FaBRICaTed CHIMneY

sYsTeM

All chimney systems must be installed with an inte-

grated Damper System / Anchor Plate installed on

top of the fireplace. Installers are cautioned to put the

chimney system together exactly as instructed in the

Venting Installation on page 12. Any variations may

have serious consequences resulting in an accident

or malfunction. If instructions are not followed, the

warranty on the product will become null and void.
Apply a 1" thick ceramic fiber blanket (Included) to

the bottom of the anchor plate.
Apply balance of gasket cement in a ¼" bead on top

of smoke dome approximately 1½" around periphery

of chimney hole. Install damper assembly on top of

unit pressing damper and insulation blanket into ce-

ment (Figure 47). Secure with four 3/16" X 1¾" ma-

sonry screws (included).

1" ceramic fiber blanket

under Anchor Plate.

Secure with

four 1/4" x

1-1/4"masonry

fastener.

1/4" bead of

gasket cement

Figure 47 - Installing Anchor Plate

Place chimney adapter onto top of damper plate and

center in opening using gasket supplied with adapt-

er.
Attach adapter with screws supplied by carefully drill-

ing holes into damper plate.
Attach damper chain stop on center rear of lintel 3”

(three inch) vertical from opening using (3) #8 ce-

ment fasteners.

aTTenTIon: Clearance to combustible construction

cannot be reduced during course of construction.

For the safe operation of the finished fireplace, these

clearances must be followed when building the

framework for the chimney system.
NOTE: The most important aspect of the installation

is maintaining the minimum required clearances to

combustible materials according to the chimney pipe

manufacturer’s recommendations, otherwise a po-

tential fire hazard may occur.

WaRnInG: do not interchange chimney parts

with any other parts except those specifically

required by FMI PRodUCTs, llC otherwise a

potential hazardous condition may be created.

Advertising
This manual is related to the following products: