www.fmiproducts.com

125160-01A

8

WaRnInG: Failure to position the parts in accordance with these diagrams or failure to use only

parts specifically approved with this appliance may result in property damage or personal injury.

18" MIN*

½"

MIN**

2" MIN. CLEARANCE TO

COMBUSTIBLES AROUND

SIDES, REAR AND TOP OF

FIREPLACE DOME

W

*IF WOOD FRAMING IS UTILIZED IT

MUST BE HELD 18" MIN. FROM TOP

OF LINTEL AND 2" MIN.CLEARANCE

MUST BE MAINTAINED ALL AROUND

FIREPLACE DOME.

**IF METAL FRAMING IS USED MAINTAIN

A ½ INCH MIN. AIR SPACE FROM TOP

OF LINTEL.

Model

W

MM33

41”

MM39

47”

MM44

52”

MM49

57”

MM63

71”

MAINTAIN THE 2" CLEARANCE TO

COMBUSTIBLES ABOVE THE DOME. DO

NOT ATTACH COMBUSTIBLE MATERIALS

ON TOP OF THE DOME.

Figure 7: Framing Dimensions for Non-Combustible Floor Systems

* MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS.

** MEASURED FROM FLOOR TO TOP OF FIREBRICK LINER.

18" MIN*

MAINTAIN THE 2" CLEARANCE

TO COMBUSTIBLES ABOVE

THE DOME. DO NOT ATTACH

COMBUSTIBLE MATERIALS

ON TOP OF THE DOME.

H**

8" MIN*

Condition

dim. H**

with 6" platform

10"

with 8" platform

12"

without platform

3"

NON-COMBUSTIBLE

FACING (NOT SUPPLIED).

Figure 6: Framing Dimensions for Combustible Floor Systems

pre-installation preparation

Continued