2 data break, Data break – FUJITSU CM71-00329-7E User Manual

Page 123

Advertising
background image

113

CHAPTER2 Dependence Functions

2.3.4.2

Data Break

This function aborts the program execution when a data access (read/write) is made to
a specified address.

Data Break

This function aborts program execution when a data access (read/write) is made to a specified address. Up

to two breakpoints can be set.

When the data break occurs, the following message appears at the status bar.

Break at address by data break at access address

How to set

Set the data break follows:

Command

- SET DATABREAK

For details, refer to "3.9 SET DATABREAK (type 2)" in "SOFTUNE Workbench Command

Reference Manual".

Dialog

- "Data" tab in breakpoint setting dialog

For details, refer to "4.6.4 Breakpoint" in "SOFTUNE Workbench Operation Manual".

If the user sets a data monitoring condition, the data break can be used as a data watch break.

For the data monitoring condition, refer to "2.3.4.9 Data Watch Break".

Note:

The data break requires the following caution:

The data break can be used only when the FR60Lite or FR80S is used. For details, refer to "2.3.4
Break".

Advertising