FUJITSU CM71-00329-7E User Manual

Page 191

Advertising
background image

181

CHAPTER2 Dependence Functions

■ Specifications of Sequencer

Table 2.4-2 shows the specifications of the sequencer for the emulator debugger (MB2100-01).

■ Setting

Sequencer control can be set as follows.

●

Dialog

- Sequence Setup Dialog

For details, refer to "4.6.6 Sequence" in "SOFTUNE Workbench Operation Manual".

●

Command

1. SET EVENT

2. SET SEQUENCE

For details, refer to "3.15 SET EVENT" or "3.31 SET SEQUENCE (type2)" in "SOFTUNE Workbench

Command Reference Manual".

Notes:

•

When the pass count mode is a passing count break mode, this function cannot be used.

•

For details, refer to "2.4.3.2 Switching Debug Function".

•

Depending on the output timing of external trace data, the actual order of code execution may
change places with the order of data hit information. For this reason, if a code event and a data
event occur close to each other, normal transition may not occur.

•

A sequencer shares points with the following functions. The maximum number of sequencer
varies depending on how those functions are used.

- Code break

- Data break

- Data watch break

- Trace trigger

•

If a data event is set to the sequencer, the data event may stop after a few steps of instructions
following the instruction with detection access are executed.

Table 2.4-2 Specifications of Sequencer

Function

Specification

No. of levels

2 levels

Restart function

Available (one)

Conditions of each
event
(Code/data)

Address
Pass count : 1 to 1048575
Attribute

: Read/write

Data size

: Byte, half-word, word

(Attribute and data size can be specified only for data events.)

Operation when
conditions are met

Level 1 : Moves to level 2
Level 2 : Terminates the sequencer
Restart : Starts the sequencer

Advertising