116

CHAPTER2 Dependence Functions

2.3.4.4

Data Event Break

This function uses breakpoints contained in the evaluation chip. The address mask,
data size, access type, and sequential mode can be set.

Data Event Break

This function uses breakpoints contained in the evaluation chip. The address mask, data size (byte/half

word/word), and access attributes (read/write) can be set.

Up to two breakpoints can be set and used in two modes.

OR mode (if a hit is found in either data event 1 or 2, a break occurs)

Sequential mode (if a hit is found in data events 1 and 2 in this order, a break occurs)

When the data event break occurs, the following message appears at the status bar.

OR mode
Break at address by data event break (No.: Data event number)

Sequential mode
Break at address by data event break (sequential)

How to set

Set the data event break as follows.

Command

- SET DATAEVENT

- SET SEQUENCE/ON (only in sequential mode)

For details, refer to "3.24 SET DATAEVENT" in "SOFTUNE Workbench Command Reference

Manual".

Dialog

- "Data" tab in event setting dialog

For details, refer to "4.6.5 Event" in "SOFTUNE Workbench Operation Manual".

Only in the OR mode, if the user sets a data monitoring condition, the data event break can be used as a

data watch break.

For the data monitoring condition, refer to "2.3.4.9 Data Watch Break".