138

CHAPTER2 Dependence Functions

■ Setting Events

Set events using the SET EVENT command.

The starting/ending point of time measurement and points to measure pass count are specified by events.

Events at 4 points (1 to 4) can be set. However, in the performance measurement, the intervals, starting

event number and ending event number are fixed in the following combination.

- Measuring Time

Two intervals have the following fixed event number combination.

- Measuring Count

The specified events become performance measurement points automatically.

■ Executing Program

Start measuring when executing a program by using the GO or CALL command. If a break occurs during

interval time measurement, the data for this specific interval is discarded.

■ Displaying Performance Measurement Data

Display performance measurement data by using the SHOW PERFORMANCE command.

■ Clearing Performance Measurement Data

Clear performance measurement data by using the CLEAR PERFORMANCE command.

[Example]

>CLEAR PERFORMANC

>

Interval

Starting Event Number

Ending Even Number

1

1

2

2

3

4