Frymaster GC User Manual

Page 12

Advertising
background image

2-5

6.

Connect the desired drain plumbing to the 1¼–inch drain valve.

7.

Test the cooker electrical system:

a. Plug the cooker electrical cord into a grounded electrical receptacle of appropriate voltage.

(Check the rating plate on the cooker door to determine the proper voltage).

b. Place the power switch in the ON position and verify that the display indicates –

LO

.

c. Place the cooker power switch in the OFF position. Verify that the display is blank.

8. Refer to the rating plate on the inside of the cooker door to verify that the cooker is configured

for the types of gas being supplied before connecting the quick-disconnect device or piping from
the gas supply line.

9. Refer to the table below to verify the minimum and maximum gas supply pressures for the type of

gas being used.

Gas

Normal (Pn)

(mbar)

(1)

Minimum (Pmin)

(mbar)

(1)

Maximum (Pmax)

(mbar)

(1)

G20

20

17

25

G25

20 or 25

20

30

G31

30 or 37

25

35 or 45

G31

50

42,5

57,5

CE Standard

for Incoming Gas Pressures

(1) mbar = 10,2mm H

2

O

References for CE Standard are Tables 6 and A.2 of EN 203-1:1993

Gas

Minimum

Maximum

Natural

6.0" WC

1.62 kPa

16.19 mbar

14" WC

3.48 kPa

34.87 mbar

Propane

11" WC

2.74 kPa

27.37 mbar

14" WC

3.48 kPa

34.87 mbar

Non-CE Standard

for Incoming Gas Pressures

Advertising